Case Study | KMbalancer II+ in The Field: Boiler ID Fan Vibration Diagnosis And Balancing
A large chemical plant in Lianyungang reported excessive vibration on a boiler induced-draft fan, with rising risk to continuous operation. They needed dynamic balancing and vibration diagnostics - urgently.
We went on site with the KMbalancer II+ vibration analyzer and field balancer. The data pointed to two distinct causes:
1. Rotor unbalance - a dominant 1× running-speed component, the underlying driver of the high vibration. Corrected on site by field balancing.
2. Foundation looseness / insufficient rigidity - high axial amplitude, a pronounced 3× component and successive peaks at multiple harmonics. With unbalance ruled out, the cause was a loose right-side foundation and insufficient base stiffness - a structural fault.
Key data - axial RMS at the bearing housing: Before balancing: 9.45 mm/s

Axial vibration was the critical dimension in this case. The numbers tell the story: balancing fixed the rotor and cut vibration by nearly 40%; what remains is governed by foundation stiffness, which balancing cannot correct.One visit, two answers. That is what a spectrum is for - telling you what to fix, and what to rebuild.